Home
| Databases
| WorldLII
| Search
| Feedback
Maltese Laws |
PRODUCT SAFETY ACT (CAP. 427)Aerosol Dispensers (Amendment) Regulations, 2009
IN exercise of the powers conferred by articles 38 to 40 of the Product Safety Act, the Minister of Finance, the Economy and Investment, has on the advice of the Malta Standards Authority, made the following regulations:-
1. (1) The title of these regulations is the Aerosols Dispensers (Amendment) Regulations, 2009 and they shall be read and construed as one with the Aerosols Dispensers Regulations,2002, hereinafter referred to as “the principal regulations”.
(2) These regulations shall come into force on 29th
December, 2010.
2. Regulation 5 of the principal requirements shall be amended as follows:(a) immediately after point 5.2.5 thereof, there shall be added the following:
“5.2.6. Where an aerosol dispenser contains flammable components as defined in point 1.8 of the Schedule but the aerosol dispenser is not considered as “flammable” or “extremely flammable” according to the criteria set out in point 1.9 of the Schedule, the quantity of flammable material contained in the aerosol dispenser must be stated clearly on the label, in the form of the following legible and indelible wording: “X % by mass of the contents are flammable”; and
(b) sub-regulation 5.5 thereof shall be deleted.
3. The Schedule to the principal regulations, shall be amended as follows:Citation and commencement.
L.N. 145 of 2002
.
Amends regulation
5 of the principal regulations.
Amends the Schedule to the principal regulations.
B 356 VERŻJONI ELETTRONIKA
contain any component which is classified as flammable:
1.8.1 flammable liquid means a liquid having a flashpoint of not more than 93 °C;
1.8.2 flammable solid means a solid substance or mixture which is readily combustible, or may cause or contribute to fire as a
result of friction. Readily combustible solids are powdered, granular, or pasty substances or mixtures which are dangerous if they
can be easily ignited by brief contact with an ignition source, such as a burning match, and if the flame spreads rapidly; and
1.8.3 flammable gas means a gas or gas mixture having a flammable range with air at 20 °C and a standard pressure of 1,013 bar;
This definition does not cover pyrophoric, self-heating or water- reactive substances and mixtures, which shall never be components
of aerosol contents.”;
(b) immediately after point 1.8 thereof, there shall be added the following new point:
“1.9. Flammable aerosols
For the purpose of this Directive, an aerosol is considered as non- flammable”, “flammable” or “extremely flammable” according
to its chemical heat of combustion and mass content of flammable components, as follows:
(a) the aerosol is classified as “extremely flammable” if it contains 85 % or more flammable components and the chemical
heat of combustion exceeds or is equal to 30 kJ/g;
(b) the aerosol is classified as “non-flammable” if it contains 1% or less flammable components and the chemical heat of combustion
is less than 20 kJ/g; and
(c) all other aerosols will be submitted to the following flammability classification procedures or shall be classified as “extremely
flammable”. The ignition distance test, the enclosed space test and the foam flammability test shall comply with point 6.3.
1.9.1. Flammable spray aerosols
In the case of spray aerosols the classification shall be made taking into account the chemical heat of combustion and on the basis
of the results of the ignition distance test, as follows:
1.9.1.1 If the chemical heat of combustion is less than 20 kJ/g:
B 357
1.9.1.1.1 the aerosol is classified as “flammable” if ignition occurs at a distance equal or greater than 15 cm but less than
75 cm;
1.9.1.1.2 the aerosol is classified as “extremely flammable” if ignition occurs at a distance of 75 cm or more; and
1.9.1.1.3 if no ignition occurs in the ignition distance test, the enclosed space test shall be performed and in this case, the aerosol
is classified as “flammable” if the time equivalent is less than or equal to 300 s/m3 or the deflagration density is less than
or equal to 300 g/m3; otherwise the aerosol is classified as “non- flammable”.
1.9.1.2 If the chemical heat of combustion is equal to or more than 20 kJ/g, the aerosol is classified as “extremely flammable”
if ignition occurs at a distance of 75 cm or more; otherwise the aerosol is classified as “flammable”.
1.9.2. Flammable foam aerosols
In the case of foam aerosols, the classification shall be made on the basis of the results of the foam flammability test.
1.9.2.1 The aerosol product shall be classified as “extremely flammable” if:
1.9.2.1.1 the flame height is 20 cm or more and the flame duration is two seconds or more; or
1.9.2.1.2 the flame height is 4 cm or more and the flame duration is seven seconds or more.
1.9.2.2 The aerosol product which does not meet the criteria in (a) is classified as “flammable” if the flame height is 4 cm
or more and the flame duration is two seconds or more.”;
(c) immediately after the new point 1.9 thereof, there shall added the following new point:
“1.10. Chemical Heat of Combustion
The chemical heat of combustion ΔHc shall be either determined
B 358 VERŻJONI ELETTRONIKA
by:
1.10.1 acknowledged rules of technology, described e.g. in standards such as ASTM D 240, ISO 13943 86.1 to 86.3 and NFPA 30B, or found
in the scientifically established literature; or
1.10.2 applying the following calculation method:
The chemical heat of combustion (ΔHc), in kilojoules per gram (kJ/g), can be calculated as the product of the theoretical heat of combustion (ΔHcomb), and a combustion efficiency, usually less than 1,0 (a typical combustion efficiency is 0,95 or 95 %).
For a composite aerosol formulation, the chemical heat of combustion is the summation of the weighted heats of combustion
for the individual components, as follows:
ΔHc = [wi% x ΔHC(i)]
where:
ΔHc = chemical heat of combustion (kJ/g) of the product;
wi% = mass fraction of component i in the product;
ΔHc(i) = specific heat of combustion (kJ/g) of component i in the product.
The person responsible for the marketing of the aerosol dispenser shall describe the method used for determining the chemical heat
of combustion in a document to be made readily available in an official Community language at the address specified on
the label in accordance with point 5.2.1 of Regulation 5.2, if the chemical heat of combustion is used as a parameter for assessing
the flammability of aerosols according to the provisions of this Regulation”;
(d) immediately after the heading to Section 2 General provisions, there shall be added the following point:
“2.0 Without prejudice to specific provisions of the Annex on requirements related to the flammability and pressure hazard, the
person responsible for the marketing of aerosol dispensers is under an obligation to analyse the hazards in order to identify those
which apply to his aerosol dispensers. Where appropriate, this analysis shall include a consideration of the risks resulting from
the inhalation of the spray ejected by the aerosol dispenser under normal and reasonably foreseeable conditions of use, taking into
account droplet size distribution in conjunction with
B 359
physical and chemical properties of the contents. He must then
design, construct and test it and, if applicable, draft special
statements concerning its use, taking account of his analysis.”; (e) point 2.2(b) thereof, shall be substituted by the following:
“(b) Where the aerosol is classified as “flammable” or “extremely
flammable” according to the criteria of point 1.9:
(i) the flame symbol, in accordance with the model in Annex II to
Directive 67/548/EEC;
(ii) the indication “flammable” or “extremely flammable.”;
(f) in point 2.3 thereof, for paragraph (a) and (b) there shall be substituted the following:
“(a) Whatever its contents, any additional operating precautions which alert consumers to the specific dangers of the product;
if the aerosol dispenser is accompanied by separate instructions for use, the latter must also reflect such operating precautions;
(b) Where the aerosol is classified as “flammable” or “extremely flammable” according to the criteria of point 1.9, the following
warnings:
(i) the safety phrases S2 and S16 laid down in Annex IV to
Directive 67/548/EEC;
(ii) “Do not spray on a naked flame or any incandescent material”.”;
(g) immediately after point 2.3 thereof, there shall be added the following: “2.4. Volume of the liquid phase
The volume of the liquid phase at 50 °C shall not exceed 90 % of the net capacity.”;
(h) for point 3.1.2. thereof, there shall be substituted the following: “3.1.2. Filling
At 50 °C, the pressure in the aerosol dispenser must not exceed
12 bar.
However, if the aerosol does not contain a gas or mixture of gases having a flammable range with air at 20°C and a standard pressure
of 1,013 bar, the maximum allowable pressure at 50
B 360 VERŻJONI ELETTRONIKA
°C is 13,2 bar.”
(i) points 3.1.3., 4.1.5. and 4.2.4. thereof shall be deleted.
(j) for point 6.1.4 thereof, there shall be substituted the following: “6.1.4. Final inspection of filled aerosol dispensers
6.1.4.1. Aerosol dispensers shall be subject to one of the following final test methods.
6.1.4.1.1 Hot water bath test
Each filled aerosol dispenser shall be immersed in a hot water bath.
6.1.4.1.1.1 The temperature of the water bath and the duration of the test shall be such that the internal pressure reaches that
which would be exerted by its contents at a uniform temperature of 50 °C.
6.1.4.1.1.2 Any aerosol dispenser showing visible permanent distortion or a leak must be rejected.
6.1.4.1.2 Hot final test methods
Other methods for heating the contents of aerosol dispensers may be used if they guarantee that the pressure and temperature in each
filled aerosol dispenser reach the values required for the hot water bath test and distortions and leaks are detected with same precision
as in the case of the hot water bath test.
6.1.4.1.3 Cold final test methods
An alternative cold final test method may be used if it is in accordance with the provisions of an alternative method to the
hot water bath test for aerosol dispensers specified in point 6.2.4.3.2.2 of Annex A to Directive 94/55/EC.
6.1.4.2. For aerosol dispensers the contents of which undergo a physical or chemical transformation changing their pressure
characteristics after filling and before first use, cold final test methods according to point 6.1.4.1.3 should be applied.
B 361
6.1.4.3. In case of test methods according to points 6.1.4.1.2 and
6.1.4.1.3:
6.1.4.3.1 The test method must be approved by a competent authority.
6.1.4.3.2 The person responsible for the marketing of aerosol dispensers must submit an application for approval to a competent
authority. The application must be accompanied by the technical file describing the method.
6.1.4.3.3 The person responsible for the marketing of aerosol dispensers must, for surveillance purposes, keep the approval of
the competent authority, the technical file describing the method and, if applicable, control reports readily available at the address
specified on the label in accordance with point 5.2.1 of Regulation
5.2.
6.1.4.3.4 The technical file must be established in an official Community language or a certified copy thereof must be available.
6.1.4.3.5 “competent authority” means the authority designated in each Member State under Directive 94/55/EC.”; and
(k) immediately after point 6.2 thereof, there shall be added the following: “6.3. Tests on the flammability of aerosols
6.3.1. Ignition distance test for spray aerosols
6.3.1.1. Introduction
6.3.1.1.1. This test standard describes the method to determine the ignition distance of an aerosol spray in order to assess the
associated flame risk. The aerosol is sprayed in the direction of an ignition source at intervals of 15 cm to observe if ignition
and sustained combustion of the spray takes place. Ignition and sustained combustion is defined as when a stable flame is maintained
for at least five seconds. The ignition source is defined as a gas burner with a blue, non-luminous flame 4-5 cm in height.
6.3.1.1.2. This test is applicable to aerosol products with a spray distance of 15 cm or more. Aerosol products with a spray distance
of less than 15 cm such as dispensing
B 362 VERŻJONI ELETTRONIKA
foams, mousses, gels and pastes or fitted with a metering valve, are excluded from this test. Aerosol products that dispense foams,
mousses, gels or pastes are subject to testing under the aerosol foam flammability test.
6.3.1.2. Apparatus and material
6.3.1.2.1. The following apparatus is required:
Water bath maintained at 20 °C accurate to ± 1 °C Calibrated laboratory scales (balance) accurate to ± 0,1 g Chronometer
(stopwatch) accurate to ± 0,2 s Graduated scale, support and clamp graduations in cm Gas burner with support
and clamp
Thermometer accurate to ± 1 °C Hygrometer accurate
to ± 5 % Pressure gauge accurate to ± 0,1 bar
6.3.1.3. Procedure
6.3.1.3.1. General requirements
6.3.1.3.1.1. Before testing, each aerosol dispenser shall be conditioned and then primed by discharging for approximately one second.
The purpose of this action is to remove non-homogeneous material from the diptube.
6.3.1.3.1.2. The instructions of use shall be strictly followed, including whether the dispenser is intended to be
used in the upright or inverted position. When shaking is required, shake immediately before testing.
6.3.1.3.1.3. The test shall be carried out in a draught-free environment capable of ventilation, with the temperature controlled at
20 °C ± 5 °C and relative humidity in the range 30-80 %.
6.3.1.3.1.4. Each aerosol dispenser is to be tested:
(a) when full according to the complete
B 363
procedure, with the gas burner in the range of 15-90 cm distance from the actuator of the aerosol can;
(b) when 10-12 % full nominal (% by mass) only one test, either at 15 cm distance from the actuator when the spray from a full
can did not ignite at all, or at the flame ignition distance of the spray of a full can plus 15 cm.
6.3.1.3.1.5. During the test, the can shall be positioned as indicated by label instructions. The ignition source shall be positioned
accordingly.
6.3.1.3.1.6. The following procedure requires testing the spray at intervals of 15 cm between the burner flame and the aerosol
actuator, in the range of
15-90 cm. It is efficient to start at 60 cm distance between burner flame and aerosol actuator. The distance between
burner flame and aerosol actuator shall be increased by 15 cm in the case of an ignition of the spray at 60 cm distance. The distance
shall be decreased by
15 cm in the case of no ignition at 60 cm distance between burner flame and aerosol actuator. The aim of the procedure is to determine
the maximum distance between aerosol actuator and burner flame that leads to sustained combustion of the spray or to determine that
ignition could not be obtained at
15 cm distance between the burner flame and
the aerosol's actuator.
6.3.1.3.2. Test procedure
(a) a minimum of 3 full aerosol dispensers per product shall be conditioned to 20 °C ± 1 °C with at least 95 % of the
dispenser immersed in the water for at least 30 min before each test (if the aerosol is fully immersed, 30 min conditioning is sufficient);
(b) comply with general requirements. Record the temperature and relative humidity of the environment;
(c) weigh an aerosol dispenser and note its mass;
(d) determine the internal pressure and initial
B 364 VERŻJONI ELETTRONIKA
discharge rate at 20 °C ± 1 °C (to eliminate faulty or partly filled aerosol dispensers);
(e) support the gas burner on a flat horizontal surface or fix the burner to a support by means of a clamp;
(f) ignite the gas burner; the flame shall be non- luminous and approximately 4-5 cm high;
(g) place the actuator's exit orifice at the required distance from the flame. The aerosol shall be tested in the position
it is designed to be used, e.g. upright or inverted;
(h) level the actuator's orifice and burner flame, ensuring that the orifice is properly directed towards and aligned with the
flame (see Figure
6.3.1.1). The spray shall be expelled through the top half of the flame;
Figure 6.3.1.1
<.. image removed ..>
(i) comply with the general requirements regarding shaking of the dispenser;
(j) actuate the valve of the aerosol dispenser, to discharge its contents for five seconds, unless ignition occurs. If ignition
occurs, continue discharging and time the duration of the flame for five seconds, from the start of ignition;
(k) note the ignition results for the distance between the gas burner and the aerosol dispenser in the table provided;
(l) if no ignition occurs during step (j), the aerosol shall be tested in alternative orientations, e.g. inverted for upright
use products, to check if ignition is obtained;
(m) repeat steps (g) to (l) twice more (a total of 3)
B 365
for the same can at the same distance between the gas burner and the aerosol actuator;
(n) repeat the test procedure for another two aerosol cans of the same product at the same distance between gas burner and aerosol
actuator;
(o) repeat steps (g) to (n) of the test procedure at a distance between 15 and 90 cm between the actuator of the aerosol can and
the burner flame depending on the outcome of each test (see also
6.3.1.3.1.4 and 6.3.1.3.1.5);
(p) if no ignition occurs at 15 cm, the procedure is finished for initially full cans. The procedure is also finished when ignition
and sustained combustion is obtained at a distance of 90 cm. If ignition could not be obtained at 15 cm distance, record that ignition
did not occur. The maximum distance between burner flame and the aerosol's actuator for which an ignition and sustained combustion
was observed is noted as the “ignition distance”, in all other circumstances;
(q) one test shall also be conducted on three cans of
10-12 % nominal fill level. These cans shall be
tested at a distance between the aerosol's actuator and the burner flame of the ‘flame ignition distance of full
cans + 15 cm’;
(r) discharge an aerosol can to a 10-12 % nominal fill level (by mass) in bursts of 30 seconds maximum. Observe a 300 seconds
minimum time period between bursts. During this interim period dispensers shall be placed in the water bath for conditioning;
(s) repeat steps (g) to (n) for 10-12 % nominal fill aerosol cans, omitting steps (l) and (m). This test shall only be performed
with the aerosol in one position, e.g. upright or inverted, corresponding with that which produced the ignition (if any) for filled
cans; and
(t) record all results in the Table 6.3.1.1 as shown below.
6.3.1.3.2.1. All experiments shall be performed in a fume hood in a room that may be well ventilated. Ventilation of the fume hood
and room can be
B 366 VERŻJONI ELETTRONIKA
applied for at least three minutes after each test. Take all necessary safety precautions to prevent the inhalation of combustion
products.
6.3.1.3.2.2. The cans with a 10-12 % nominal fill level shall be tested only once. The result tables need only one result per can
indicated.
6.3.1.3.2.3. When the test in the position in which the dispenser is designed to be used gives a negative result, the test
shall be repeated in the position of the dispenser most likely to result in a positive result.
6.3.1.4. Method of assessing results
6.3.1.4.1 All the results shall be recorded. Table 6.3.1.1 below shows the model of ‘result table’ to be used.
Table 6.3.1.1
Date | Temperature … OC Relevant humidity … % | |||
Name of product | ||||
Net volume | Can 1 | Can 2 | Can 3 | |
Initial level of filling | ||||
Dispenser distance | Test | 1 2 3 | 1 2 3 | 1 2 3 |
15 cm | Ignition? Y or N | |||
30 cm | Ignition? Y or N | |||
45 cm | Ignition? Y or N | |||
60 cm | Ignition? Y or N | |||
75 cm | Ignition? Y or N | |||
90 cm | Ignition? Y or N | |||
Observations – including can position |
6.3.2. Enclosed space ignition test
6.3.2.1. Introduction
B 367
This test standard describes the method to assess the flammability of products emerging from aerosol dispensers due to their
propensity to ignite in an enclosed or confined space. The contents of an aerosol dispenser are sprayed into a cylindrical test vessel
containing a burning candle. If an observable ignition occurs, the elapsed time and amount discharged is noted.
6.3.2.2. Apparatus and material
6.3.2.2.1 The following apparatus is required:
Chronometer (stopwatch) accurate to ± 0,2 s Water bath maintained at 20 °C accurate to ± 1 °C Calibrated
laboratory scales (balance) accurate to ± 0,1 g Thermometer accurate to ± 1 °C Hygrometer
accurate to ± 5 %
Pressure gauge accurate to ± 0,1 bar
Cylindrical test vessel as detailed below
6.3.2.2.2 Preparation of test apparatus
6.3.2.2.2.1. A cylindrical vessel approximately 200 dm3 volume, approximately 600 mm in diameter and approximately 720 mm long
and open at one end shall be modified as follows:
6.3.2.2.2.1.1 a closure system consisting of a hinged cover shall be matched to the open end of the receptacle; or
6.3.2.2.2.1.2 a plastic film 0,01 to 0,02 mm thick may be used as a closure system. If the test is carried out with a plastic film
this must be used as described below: Stretch the film over the open end of the drum and hold it in place with an elastic band. The
strength of the band shall be such that when placed around the drum resting on its side, it stretches by only 25 mm when a mass of
0,45 kg is attached to its lowest point. Cut a 25 mm slit in the film, starting 50 mm
B 368 VERŻJONI ELETTRONIKA
from the edge of the drum. Ensure that the film is taut; or
6.3.2.2.2.1.3 at the other end of the drum drill a 50 mm diameter hole 100 mm from the edge in such a way that the orifice is uppermost
when the receptacle is laid down and ready for the test (Figure
6.3.2.1.)
Figure 6.3.2.1
<.. image removed ..>
6.3.2.2.2.1.4 on a 200 × 200 mm metal support place a paraffin wax candle 20 to 40 mm in diameter and 100 mm high. The candle shall
be replaced when having a height of less than 80 mm. The candle's flame is protected from the action of the spray by a
150 mm wide, 200 mm high deflector. This includes the plane inclined at 45° produced 150 mm from the base of the deflector
(Figure
6.3.2.2.);
Figure 6.3.2.2
<.. image removed ..>
6.3.2.2.2.1.5 the candle placed on the metal support shall be positioned midway between the two ends of the drum (Figure
6.3.2.3);
Figure 6.3.2.3
B 369
<.. image removed ..>
6.3.2.2.2.1.6 the drum is laid on the ground or on a support at a spot where the temperature is between 15 °C and 25 °C. The product
to be tested will be sprayed within the drum of roughly 200 dm3 in which there will be a source of ignition.
6.3.2.2.2.2. Usually, the product leaves the aerosol can at an angle of 90° relevant to the vertical axis of the can. The layout
and procedure described refers
to this kind of aerosol product. In the case of unusually operating aerosols (e.g. vertical-spray aerosol dispensers) it will be necessary
to record changes to equipment and procedures in accordance with good laboratory practice, such as ISO/IEC 17025:1999 General requirements
for the competence of testing and calibration laboratories.
6.3.2.3. Procedure
6.3.2.3.1. General requirements
6.3.2.3.1.1. Before testing, each aerosol dispenser shall be conditioned and then primed by discharging for approximately 1 second.
The purpose of this action is to remove non-homogeneous material from the diptube.
6.3.2.3.1.2. The instructions of use shall be strictly followed, including whether the dispenser is intended to be used in the upright
or inverted position. When shaking is required, shake immediately before testing.
B 370 VERŻJONI ELETTRONIKA
6.3.2.3.1.3. The tests shall be carried out in a draught-free environment capable of ventilation, with the temperature controlled
at 20 °C ± 5 °C and relative humidity in the range 30-80 %.
6.3.2.3.2. Test procedure
6.3.2.3.2.1 a minimum of 3 full aerosol dispensers per product shall be conditioned to 20 °C ± 1 °C in a water bath with at
least 95 % of the dispenser immersed in the water for at least 30 min (if the aerosol is fully immersed, 30 min conditioning is sufficient);
6.3.2.3.2.2 measure or calculate the actual volume of the drum in dm3;
6.3.2.3.2.3 comply with general requirements. Record the temperature and relative humidity of the environment;
6.3.2.3.2.4 determine the internal pressure and initial discharge rate at 20°C ± 1°C (to eliminate faulty or partly filled aerosol
dispensers);
6.3.2.3.2.5 weigh one of the aerosol dispensers and note its mass;
6.3.2.3.2.6 light the candle and apply the closure system
(cover or plastic film);
6.3.2.3.2.7 place the aerosol dispenser actuator orifice 35 mm or closer for a wide spray product, from the centre of the entrance
hole in the drum. Start the chronometer (stopwatch) and following the instructions for use of the product; direct the spray towards
the centre of the opposite extremity (cover or plastic film). The aerosol shall be tested in the position it is designed to be used,
e.g. upright or inverted;
6.3.2.3.2.8 spray until ignition occurs. Stop the chronometer and note the time elapsed. Re- weigh the aerosol dispenser
and note its mass;
6.3.2.3.2.9 ventilate and clean the drum removing any residue likely to affect subsequent tests. Allow the drum to cool if necessary;
and
6.3.2.3.2.10 repeat the test procedure steps 6.3.2.3.2.4 to
B 371
6.3.2.3.2.9 for another two aerosol dispensers of the same product (three in total, note: each dispenser is only tested once);
6.3.2.4. Method of assessing results
6.3.2.4.1. A test report containing the following information shall be drawn up:
6.3.2.4.1.1 the product tested and its references;
6.3.2.4.1.2 the internal pressure and discharge rate of the aerosol dispenser;
6.3.2.4.1.3 the temperature and relative air humidity of the room;
6.3.2.4.1.4 for each test, the discharge time (s) needed to achieve ignition (if the product does not ignite, state this);
6.3.2.4.1.5 the mass of the product sprayed during each test
(in g);
6.3.2.4.1.6 the actual volume of the drum (in dm3).
6.3.2.4.2. The time equivalent (teq) needed to achieve ignition in one cubic metre can be calculated as follows:
teq = 1 000 × discharge time (s) Actual volume of drum (dm3)
6.3.2.4.3 The deflagration density (Ddef) needed to achieve ignition during the test may also be calculated as follows:
Ddef =1 000 × Amount of product dispensed
Actual volume of drum (dm3)
6.3.3. Aerosol foam flammability test
6.3.3.1. Introduction
6.3.3.1.1. This test standard describes the method to determine the flammability of an aerosol spray emitted in the form of a foam,
mousse, gel or paste. An aerosol, which emits a foam, mousse, gel or paste is sprayed (approximately 5 g) on a watchglass and an
ignition source (candle, wax taper, match or lighter) is placed at the base of the watchglass to observe if ignition
B 372 VERŻJONI ELETTRONIKA
and sustained combustion of the foam, mousse, gel or paste occurs. Ignition is defined as a stable flame maintained for at least two
seconds and a minimum 4 cm in height.
6.3.3.2. Apparatus and material
6.3.3.2.1. The following apparatus is required:
Graduated scale, support and clamp gradations in cm Fire-resistant watchglass roughly 150 mm in diameter Chronometer (stopwatch)
accurate to ± 0,2 s Candle, wax taper, match or lighter
Calibrated laboratory scales (balance) accurate to ± 0,1 g Water bath maintained at 20 °C accurate to ± 1 °C Thermometer
accurate to ± 1 °C Hygrometer accurate to ± 5
%
Pressure gauge accurate to ± 0,1 bar
6.3.3.2.2. The watchglass is placed on a fire-resistant surface within a draught-free area that may be ventilated after each
test. The graduated scale is positioned exactly behind the watchglass and held vertically by means of a support and clamp.
6.3.3.2.3. The scale is positioned in such a way that its origin is on a level with the watchglass base in a horizontal plane.
6.3.3.3. Procedure
6.3.3.3.1. General requirements
6.3.3.3.1.1. Before testing, each aerosol dispenser shall be conditioned and then primed by discharging for approximately 1 second.
The purpose of this action is to remove non-homogeneous material from the diptube.
6.3.3.3.1.2. The instructions of use shall be strictly followed, including whether the dispenser is
B 373
intended to be used in the upright or inverted position. When shaking is required, shake immediately before testing.
6.3.3.3.1.3. The tests shall be carried out in a draught-free environment capable of ventilation, with the temperature controlled
at 20 °C ± 5 °C and relative humidity in the range of 30-80 %.
6.3.3.3.2 Test procedure
6.3.3.3.2.1 a minimum of four full aerosol dispensers per product shall be conditioned to 20 °C ± 1 °C with at least 95 %
of the dispenser immersed in the water for at least 30 min before each test (if the aerosol is fully immersed, 30 min conditioning
is sufficient);
6.3.3.3.2.2 comply with general requirements. Record the temperature and relative humidity of the environment;
6.3.3.3.2.3 determine the internal pressure at 20°C ± 1 °C (to eliminate faulty or partly filled aerosol dispensers);
6.3.3.3.2.4 measure the discharge or flow rate of the aerosol product to be examined, so that the amount of test product dispensed
can be more accurately gauged;
6.3.3.3.2.5 weigh one of the aerosol dispensers and note its mass;
6.3.3.3.2.6 on the basis of the measured discharge or flow rate and following the manufacturer's instructions, release approximately
5 g of the product onto the centre of the clean watchglass with the aim of producing a mound no higher than 25
mm;
6.3.3.3.2.7 within five seconds of completion of discharge, apply the source of ignition to the edge of the sample at its base
and at the same time start the chronometer (stopwatch). If necessary, the ignition source shall be removed from the edge of
the sample after approximately two seconds, in order to clearly observe if ignition has occurred. If no ignition of the sample is
apparent, the ignition source shall be
B 374 VERŻJONI ELETTRONIKA
reapplied to the edge of the sample;
6.3.3.3.2.8 if ignition occurs note the following points:
6.3.3.3.2.8.1 the maximum height of the flame in cm above the base of the watchglass;
6.3.3.3.2.8.2 the flame duration in s; and
6.3.3.3.2.8.3 dry and re-weigh the aerosol dispenser and calculate the mass of the released product;
6.3.3.3.2.9 ventilate the test area immediately after each test;
6.3.3.3.2.10 if ignition is not obtained and the released product remains in the form of a foam or paste throughout its
period of use, steps (e) to (i) shall be repeated. Allow the product to stand for 30 sec, 1 min, 2 min or 4 min before applying the
ignition source;
6.3.3.3.2.11 repeat the test procedure steps (e) to (j) twice more (a total of 3) for the same can; and
6.3.3.3.2.12 repeat the test procedure steps (e) to (k) for another two aerosol cans (3 cans in total) of the same product.
6.3.3.4. Method of assessing results
6.3.3.4.1. A test report containing the following information shall be drawn up:
6.3.3.4.1.1 whether the product ignites;
6.3.3.4.1.2 maximum flame height in cm;
6.3.3.4.1.3 duration of flame in s; and if
6.3.3.4.1.4 the mass of the product was tested.”.
Ippubblikat mid-Dipartiment tal-Informazzjoni (doi.gov.mt) — Valletta — Published by the Department of Information (doi.gov.mt) — Valletta
Mitbugħ fl-Istamperija tal-Gvern fuq karta riċiklata — Printed at the Government Printing Press on recycled paper <.. image removed ..>
Prezz/Price
€0.93
WorldLII:
Copyright Policy
|
Disclaimers
|
Privacy Policy
|
Feedback
URL: http://www.worldlii.org/mt/legis/laws/psa427adr200926o2009647